WLD1900

WLD1900 Series





How It Works

The WLD1900 Series liquid drainers contain a float-operated valve. When liquid enters the drainer, the float rises opening the valve which allows liquid to be drained.



Features
  • All stainless steel internals
  • Hardened valve seat for longer service life
  • Cast Iron body
  • In-line repairable


Dimension Charts Capacity












Capacity Chart


WLD1900-Series Liquid Drainers have Cast Iron Bodies ••• Parallel Pipe Connection ••• 250 psig Operating Pressures ••• All Stainless Steel Internals. Used for draining liquids from Tanks, Vessels, and piping systems containing pressurized Air or other gases.

ModelSizeTypeMax PMO (psig)Max Capacity @ Max PMO (lb/hr)
WLD1913-N-0153/4"NPT153260
WLD1913-N-0903/4"NPT902170
WLD1914-N-2001"NPT2003150
WLD1914-N-2501"NPT2502070
WLD1916-N-0151 1/2"NPT158650
WLD1915-N-0901 1/4"NPT909500
WLD1916-N-2501 1/2"NPT2508140
WLD1917-N-0152"NPT1510810
WLD1913-N-2503/4"NPT2502070
WLD1914-N-0151"NPT153260
WLD1915-N-0301 1/4"NPT304130
WLD1915-N-2001 1/4"NPT20011100
WLD1916-N-1501 1/2"NPT1509800
WLD1916-N-2001 1/2"NPT20011100
WLD1917-N-1502"NPT15012500
WLD1917-N-2502"NPT25012340
WLD1913-N-0303/4"NPT304130
WLD1913-N-1503/4"NPT1501590
WLD1913-N-2003/4"NPT2003150
WLD1914-N-0301"NPT304130
WLD1914-N-0901"NPT902170
WLD1914-N-1501"NPT1501590
WLD1915-N-0151 1/4"NPT154070
WLD1915-N-1501 1/4"NPT1509800
WLD1915-N-2501 1/4"NPT2508140
WLD1916-N-0301 1/2"NPT3011000
WLD1916-N-0901 1/2"NPT909500
WLD1917-N-0302"NPT3012000
WLD1917-N-0902"NPT9011350
WLD1917-N-2002"NPT20023800
Product Overview
WLD1900-Series Liquid Drainers have Cast Iron Bodies ••• Parallel Pipe Connection ••• 250 psig Operating Pressures ••• All Stainless Steel Internals. Used for draining liquids from Tanks, Vessels, and piping systems containing pressurized Air or other gases.
Features
• All stainless steel internals
• Hardened valve seat for longer service life
• Cast Iron body
• In-line repairable
How It Works
The WLD1900 Series liquid drainers contain a float-operated valve. When liquid enters the drainer, the float rises opening the valve which allows liquid to be drained.
Selection / Sizing / Capacities
Determine the capacity (lbs/hr) required at the specified differential pressure. Locate differential pressure on capacity chart; move down column to capacity required. Make sure to select the correct model based on the maximum inlet pressure.

Capacity in lbs/hr is based on differential pressure across the drainer. Select a model with an equal or higher PMO (max. operating pressure) than the maximum inlet pressure to the drainer. If the pressure to the drainer exceeds the PMO, the drainer may not open. If discharging to atmosphere, the differential pressure is equal to the inlet pressure.

Example:
Required to drain 3,000 lbs/hr at a differential pressure of 5 PSI. The maximum inlet pressure is 30 PSIG.

Select Model:
WLD1916-030, 11/2”, capacity up to 4,710 lbs/hr based on 5 PSI differential pressure.

Dimension and Weights
Pipe Size PMO (psig)  Weight (lbs)
 3/4", 1"  15-150 9
 1-1/4"  15-30 9
Pipe Size PMO (psig)  Weight (lbs)
3/4", 1"  200-250 20
1-1/4" 90-250 21
1-1/2" 15-250 21
Pipe Size PMO (psig)  Weight (lbs)
2" 15-250 53
Installation and Maintenance
The installation should include isolation valves to facilitate maintenance and an in-line strainer. The trap must be level and upright for the float mechanism to operate. Trap must be adequately sized and properly located in the system. Installation may require an equalizing or balancing line connected from top of drainer body to the above piping, for proper drainage.

All working components can be replaced with the drain trap remaining in the pipeline. Repair kits include float, valve seat & disc, and gaskets. For full maintenance details see Installation and Maintenance Manual.
Sample Specification
The WLD1900 Series liquid drainers contain a float-operated valve. When liquid enters the drainer, the float rises opening the valve which allows liquid to be drained.