Technical Specification
  
Size1 1/2"
ConnectionNPT
Max. Operating Pressure (psig)30
Max. Operating Temperature450°F
Design Pressure250 PSIG up to 450°F
Temperature Rating450°F @ 250 PSIG
Material Specification
  
BodyCast Iron
CoverCast Iron
GasketGarlock 3400/grafoil SLS
Cover ScrewsStainless Steel
Float304 SS
Internals300 Series SST
Valve SeatStainless Steel,17-4 PH
Valve Disc420F SS
Cross Reference
  
Spirax SarcoFA
Hoffman793
WLD1916-N-030
QTY :
Product Overview
WLD1900-Series Liquid Drainers have Cast Iron Bodies ••• Parallel Pipe Connection ••• 250 psig Operating Pressures ••• All Stainless Steel Internals. Used for draining liquids from Tanks, Vessels, and piping systems containing pressurized Air or other gases.
Features
• All stainless steel internals
• Hardened valve seat for longer service life
• Cast Iron body
• In-line repairable
How It Works
The WLD1900 Series liquid drainers contain a float-operated valve. When liquid enters the drainer, the float rises opening the valve which allows liquid to be drained.
Selection / Sizing / Capacities
Determine the capacity (lbs/hr) required at the specified differential pressure. Locate differential pressure on capacity chart; move down column to capacity required. Make sure to select the correct model based on the maximum inlet pressure.

Capacity in lbs/hr is based on differential pressure across the drainer. Select a model with an equal or higher PMO (max. operating pressure) than the maximum inlet pressure to the drainer. If the pressure to the drainer exceeds the PMO, the drainer may not open. If discharging to atmosphere, the differential pressure is equal to the inlet pressure.

Example:
Required to drain 3,000 lbs/hr at a differential pressure of 5 PSI. The maximum inlet pressure is 30 PSIG.

Select Model:
WLD1916-030, 11/2”, capacity up to 4,710 lbs/hr based on 5 PSI differential pressure.

Dimension and Weights

Weight
21 lbs.
Installation and Maintenance
The installation should include isolation valves to facilitate maintenance and an in-line strainer. The trap must be level and upright for the float mechanism to operate. Trap must be adequately sized and properly located in the system. Installation may require an equalizing or balancing line connected from top of drainer body to the above piping, for proper drainage.

All working components can be replaced with the drain trap remaining in the pipeline. Repair kits include float, valve seat & disc, and gaskets. For full maintenance details see Installation and Maintenance Manual.
Sample Specification
The WLD1900 Series liquid drainers contain a float-operated valve. When liquid enters the drainer, the float rises opening the valve which allows liquid to be drained.